■ ELECTRONIC BALLAST

ISO-9001 Certified Global Quality Approved

USTA CO. , LTD.

UL File No. E198163

Model No. EEB84

Smart Sensor

70 ~-20 Extreme Temperature 42 in 1

70 C Max Case Temp. /-20 C Start Temp.

Multi-Volt  & Lamp Compact Electronic Ballast

For Two or One 42,32,26 CF lamps or Two or one 40,39,36 or one 55,50 FT lamps or one 2D38 lamp

Description: Universal Voltage, Electronic Ballast, soft start technology for four pin lamp applications
 
Model # Voltage # of Lamps Lamp Watts Input Watts (AVE) Input Current (MAX) Power Factor Ballast Factor THD Bench Heat Test at 23℃ Ambiant Heat Crest Factor
EEB84 120 2 PLT 42W 84 0.7 0.997 0.8 3.5 55 1.4
2 PLL 40W 84 0.7 0.998 0.86 3.8 55 1.4
2 PLL 39W 65 0.54 0.998 0.55 3.2 55 1.4
2 PLT 32W 64 0.53 0.999 0.7 3.8 45 1.4
2 PLL 36W 63 0.53 0.998 0.79 3.2 55 1.4
2 PLT 26W 55 0.46 0.999 0.95 3.8 45 1.4
1 PLL 50W 46 0.38 0.997 0.76 6.2 35 1.4
1 PLL 40W 45 0.38 0.997 0.94 5.9 35 1.4
1 PLT 42W 44 0.37 0.997 0.82 6.5 35 1.4
1 PLL 55W 40 0.34 0.994 0.71 9.4 45 1.4
1 PLT 32W 36 0.30 0.99 0.69 13.6 35 1.4
1 PLL 36W 34 0.29 0.986 0.76 13 35 1.4
1 PLL 39W 34 0.29 0.985 0.56 15.8 35 1.4
1 2D  38W 32 0.27 0.985 0.58 1.4 35 1.4
1 PLT26W 28.94 0.24 0.981 0.98 19.5 30 1.5
230 2 PLL 40W 85 0.37 0.989 0.87 14 55 1.4
2 PLT 42W 83 0.37 0.989 0.84 14 55 1.4
2 PLL 39W 67 0.3 0.986 0.56 16.8 55 1.4
2 PLL 36W 65 0.29 0.985 0.8 16.2 55 1.4
2 PLT 32W 65 0.29 0.986 0.7 16.5 45 1.4
2 PLT 26W 57 0.25 0.984 0.96 15.8 45 1.4
1 PLL 40W 49 0.22 0.984 0.97 13.9 35 1.4
1 PLT 42W 47 0.21 0.985 0.82 13.7 35 1.4
1 PLL 50W 47 0.21 0.984 0.77 13.8 35 1.4
1 PLL 55W 43 0.19 0.985 0.72 14 45 1.4
1 PLL 39W 37 0.16 0.985 0.56 11.6 35 1.4
1 PLT 32W 37 0.16 0.985 0.7 12.5 35 1.4
1 PLL 36W 36 0.16 0.985 0.77 11.6 35 1.4
1 2D  38W 34 0.15 0.984 0.59 12.4 35 1.4
1 PL-T26W 29.7 0.13 0.981 0.97 14.15 30 1.5
277 2 PLL 40W 84 0.31 0.989 0.88 12.8 55 1.4
2 PLT 42W 79 0.29 0.987 0.81 13.5 55 1.4
2 PLL 39W 67 0.24 0.986 0.57 11.6 55 1.4
2 PLT 32W 67 0.25 0.987 0.72 11.3 45 1.4
2 PLL 36W 64 0.23 0.986 0.82 11.6 55 1.4
2 PLT 26W 57 0.21 0.987 0.98 9.8 55 1.4
1 PLL 40W 50 0.18 0.984 0.99 10.8 35 1.4
1 PLT 42W 49 0.18 0.978 0.84 11 35 1.4
1 PLL 50W 47 0.17 0.983 0.79 11.5 35 1.4
1 PLL 55W 45 0.16 0.983 0.74 12.2 45 1.4
1 PLL 36W 37 0.14 0.962 0.77 22 35 1.4
1 2D  38W 37 0.14 0.954 0.61 21.8 35 1.4
1 PLL 39W 37 0.14 0.965 0.58 21.2 35 1.4
1 PLT 32W 36 0.13 0.965 0.71 20.3 35 1.4
1 PLT 26W 30.31 0.12 0.904 1.02 47.62 30 1.5
Performance: Physical Parameters:
Rating: Type 1 Outdoor Length: 165mm(6.49")
IR Interference: None Width: 74mm(2.91")
Remote Wiring: 25ft. Height: 30mm(1.14")
High Power Factor Weight: 0.31kg(0.13lb)
Universal Voltage Lead Length: Plug in Connector
Auto Reset Carton: 42 pcs.
Application:
     Sound Rated: A
     Minimum Starting Temperature to -200C
     Allowed Maximum Case Temperature 700C (Full Warranty)
Safety:
     End of Lamp Life Protection Circuit
     UL Listed
     CUL Certified
     Class P Thermally Protected
     Surge Protected, Meets ANSI C62.41
     Starting Method: Program Start
Carrier Guard Protection for line power
Carrier Signals

Warranty:

USTA, warrants to the purchaser that each electronic ballast will be free from defects in material or workmanship for a period of 3 years from date of manufacture when properly installed and under normal conditions of use.



4F.,No.207 Tun-Hwa N.Rd., Taipei,Taiwan,R.O.C.

Tel:886-2-2718-2336 •Fax:886-2-2546-0350

Copyright 2002 USTA Co.,Ltd